After I had conducted my Multimeter test yesterday to determine if those red wires I had soldered onto the Switch Pod individual button terminals were power wires I realized I needed to make a minor change to this other diagram I had done for an option of using one of the Switch Pod Buttons to cycle through the Message Centre messages. The Momentary Button on the Pod closes power to ground which energizes the magnetic coil of the Relay closing the Relay's internal switch and this then if hooked up as a switch between the GND and CYC should cycle the message on the Message Centre.
Showing posts with label message centre cycle button. Show all posts
Showing posts with label message centre cycle button. Show all posts
Monday, October 27, 2014
Sunday, October 12, 2014
Hypothetical Switch Pod Button To Cycle Message Centre

Again please do NOT take my diagram here as 100 percent accurate until I mention in an updated post that it actually works right now this is just "Hypothetical" :)

I'm not 100 percent sure if it makes a difference or not in having Relay terminals 85 and 86 in a specific order. I think from some of the initial research I have done in most cases it looks like terminal 86 is Ground or Common, while 85 is your input from switch. But like I say I'm not 100 percent certain if it makes a difference as I have seen examples of the terminals being used opposite or flipped meaning that 85 was Ground and 86 was input from switch. So I have made another diagram to reflect that difference. If you try this please be sure to verify which one is correct or if it indeed makes little or no difference. I think if the Relay had a resistor inside of it then perhaps it might??
Important Note: According to one online source on Relay Basics it is quoted as saying:
"85 and 86 are the coil pins. Normally, it doesn't matter which way you pass the current, because if you hook it up backwards, the coil will still activate the relay. However, relays sometimes have an odd tendency to turn themselves back on briefly. To counter this, a diode (a one way switch) is placed between 85 and 86. This is referred to as a tamping diode. A diode wall have a very high resistance in one direction, and a very low resistance in the opposite direction. When a tamping diode is used, it is important that you hook the coil up according to polarity. If a tamping diode is used, and you hook it up backwards, you will essentially be shorting a wire out, which sucks, because you can and will burn something up."
If you are not sure if the relay you are using has such a "Tamping Diode" inside of it You can do a continuity test between them to see if a tamping diode is being used. Test with red lead of multimeter on 85 and black on 86, the reverse. If you get a reading either way, then there is a diode beyween them.
If you are not sure if the relay you are using has such a "Tamping Diode" inside of it You can do a continuity test between them to see if a tamping diode is being used. Test with red lead of multimeter on 85 and black on 86, the reverse. If you get a reading either way, then there is a diode beyween them.
Subscribe to: